DUKA One Pro 25 B Data sheet

Fresh
Air
Stylish

Consumption

guaranteed

sound level

heat recovery

Efficient and energy conscious
1-compartment ventilation solution

DUKA One Pro 25 B is a Ø100 wet room ventilation unit designed to improve the indoor climate in wet rooms such as utility rooms, bathrooms and toilets.

The unit has a pipe diameter of Ø100 mm and can be mounted horizontally through the outer wall. The DUKA One Pro 25 B can be placed in an existing Ø105 mm or 150×150 mm hole, upgrading a fresh air valve to a ventilation solution with heat recovery.

DUKA One Pro 25 B is designed to provide basic ventilation under normal conditions. When the humidity rises, it switches to ventilation in forced operation with clean extraction. When the humidity in the room is back to normal levels, the unit goes back to normal operation with heat recovery. This is especially important so that the vapour from the wet room is not moved to adjacent rooms.

During normal operation, the heat from the home will be transferred during the extraction function to the ceramic exchanger. When the fan reverses and starts blowing air into the home, the heat is recycled by preheating the outdoor air as it passes the exchanger.

The unit consists of a discreet front panel, a wall duct with ceramic exchanger, white exterior storm shield, low-energy bi-directional fans and a remote control.


Benefits and advantages
Specifically designed for bathrooms, utility rooms, and toilets
Achieve an excellent indoor climate
Reduces radon and CO₂
Prevents condensation and moisture
Efficient and energy-conscious ventilation
Easy installation, as no ducting needs to be installed in the home
Provides energy savings
No need to open and close windows

Speed step I II III
Device voltage [V/Hz] 100-240 V 50/60 Hz
Power [W] 1,2 2,3 4,3
Current [A] 0,03 0,04 0,05
Airflow in ventilation mode [m³/h] 10 20 30
Air flow rate in heat recovery mode [m³/h] 5 10 15
SFP [W/l/s] 0,43 0,41 0,52
SPI [W/m³/h] 0,12 0,12 0,14
SEL [J/m³] 432 414 516
Heat recovery rate [%] 81 71 61
m² v. 0.3 l/s 5 9 14
Sound pressure level at 1 m [dBA] 28 32 43
Sound pressure level at 3 m [dBA] 26 30 39
Noise cancellation on external noise [dBA] 40
Filter G3
Transported air temperature [°C] -15 ... +40
IP class IP 24